The SE 1052 is a versatile battery charger designed for charging various types of rechargeable batteries, including NiMH, NiCd, and Li-ion. It features multiple charging modes, automatic voltage detection, safety protections (overcharge, short-circuit, reverse polarity), LCD display with charging status indicators, and compatibility with common battery sizes (AA, AAA, C, D, 9V). Powered by 100-240V AC, 50/60Hz. Below are key sections for safety, features, installation, operation, and troubleshooting.
Key components: Main charging unit, LCD display, Battery slots (AA/AAA x 4, C/D x 2, 9V x 1), Power cord, Status LEDs.
| Feature | Description |
|---|---|
| Automatic Battery Detection | Detects battery type and voltage automatically |
| Multiple Charging Modes | Standard, Fast, Trickle, and Recovery modes |
| LCD Display | Shows charging status, voltage, current, and time |
| Battery Slots | Independent channels for AA/AAA, C/D, and 9V batteries |
| Safety Protections | Overcharge, short-circuit, reverse polarity, and over-temperature |
| Power Input | 100-240V AC, 50/60Hz universal input |
| Charging Current | Adjustable from 200mA to 1000mA |
| Compatibility | NiMH, NiCd, Li-ion (3.7V) batteries |
| Cooling Fan | Built-in fan for temperature control |
| Carrying Case | Included for portability (optional) |
Unpack and inspect contents. Place on stable, dry surface away from heat sources.
WARNING! Do not mix battery types (e.g., NiMH with Li-ion) in same charging session. Ensure correct polarity to avoid damage.
Front Panel: POWER button, MODE button, DISPLAY button, Battery slots.
LCD Indicators: Charging status (Flashing/Full), Battery type icon, Voltage (V), Current (mA), Time (HH:MM), Error codes.
Charging Modes: STANDARD (default), FAST (quick charge), TRICKLE (maintenance), RECOVERY (reconditioning). Display: Press DISPLAY to cycle through voltage, current, and time. Safety: LED indicators for overcharge (red), reverse polarity (flashing red), complete (green).
Supports NiMH, NiCd, Li-ion, and 9V rechargeable batteries.
WARNING! Do not leave batteries charging unattended for extended periods. Use only rechargeable batteries.
Overcharge Protection: Automatically stops charging when full. Short-Circuit Protection: Cuts off current if short detected. Reverse Polarity Protection: Prevents charging if batteries inserted incorrectly. Over-Temperature Protection: Reduces current or stops if charger overheats.
Unplug before cleaning. Use dry cloth only; do not use liquids. Store in cool, dry place.
CAUTION! Do not disassemble charger; no user-serviceable parts inside. Keep away from water and metal objects.
FCC Part 15: Class B digital device; complies with interference limits for residential use. CE: Meets European safety standards. RoHS: Free of hazardous substances. Copyright © 2025 SE Electronics; trademarks of SE Group. For support, visit www.se-electronics.com or contact 1-800-555-1052.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Charger not powering on | Power connection | Check wall outlet; ensure power cord is securely plugged in. |
| Battery not charging | Polarity/battery type | Check battery polarity; ensure battery is rechargeable and compatible. |
| Overheating | Ventilation/current | Ensure vents are clear; reduce charging current; move to cooler location. |
| LCD display blank | Power/backlight | Press POWER; check AC input; press DISPLAY to activate backlight. |
| Error code E1/E2 | Reverse polarity/short circuit | Remove batteries; reinsert with correct polarity; check for damaged batteries. |
Reset: Unplug charger for 30 seconds, then reconnect.
Service: 1-800-555-1052; www.se-electronics.com