Schumacher Wheeled Battery

User Manual & Safety Guide

Wheeled Battery Charger/Maintainer

Installation Guide

Tools Needed:

  • Adjustable wrench
  • Screwdrivers (flat and Phillips)
  • Wire cutters/strippers
  • Safety glasses
  • Voltage meter

Step-by-Step Installation

  1. Choose Installation Location: Select a dry, well-ventilated area on a level surface away from sparks or flames.
  2. Unpack and Inspect: Remove all packaging materials and inspect the unit for any shipping damage.
  3. Position the Unit: Place the wheeled battery charger on a stable, flat surface with wheels locked.
  4. Connect Power Cord: Plug the unit into a properly grounded 120V, 60Hz, AC only outlet. Do not use an extension cord.
  5. Battery Connection: Connect red clamp to positive (+) battery terminal, black clamp to negative (-) terminal or grounded metal.
  6. Select Charge Mode: Choose appropriate charge mode based on battery type (standard, AGM, gel, deep cycle).
  7. Initial Test: Start the charging process and monitor for proper operation and connection.
Warning: Always wear protective eyewear when working with batteries. Ensure proper ventilation to prevent gas accumulation.

Specifications

Model Series SC1355 / SC1353
Type Wheeled Battery Charger & Maintainer
Color Black/Yellow / Red/Black
Charge Rate 2/10/55/200 Amp
Battery Compatibility 6V & 12V (Standard, AGM, Gel, Deep Cycle)
Display Type Digital LCD with LED Indicators
Engine Start 200 Amp Engine Start Assist
Power Requirements 120V AC, 60Hz, 15A
Dimensions (HxWxD) 18 x 12 x 15 inches
Weight 45 lbs
Wheel Type 4-inch Rubber Wheels with Locking Casters
Charger Type Automatic Microprocessor Controlled

Warranty Information

  • Full Warranty: 1 year parts and labor
  • Transformer Warranty: 5 years on heavy-duty transformer
  • Additional Coverage: Optional extended warranty available

For warranty service, contact Schumacher Customer Service at 1-800-621-5485 or visit SchumacherElectric.com

Key Features

Multi-Stage Charging

Advanced microprocessor-controlled charging with bulk, absorption, and float stages for optimal battery health and longevity.

Battery Recondition Mode

Special mode designed to recover and recondition sulfated batteries, extending battery life and restoring performance.

200-Amp Engine Start

Powerful engine start function provides 200 amps of starting power to start vehicles with dead or weak batteries.

AGM/Gel Compatible

Special charging algorithms for AGM (Absorbent Glass Mat) and gel cell batteries to prevent overcharging and damage.

Digital Display

Clear LCD display shows voltage, charge rate, battery status, and error codes for easy monitoring and diagnostics.

Wheeled Design

Heavy-duty wheeled cart with locking casters for easy mobility around garage, shop, or job site.

Charging Modes Explained

Standard Charge

For regular lead-acid batteries, provides 10-amp charge with automatic voltage regulation

AGM/Gel Mode

Special algorithm for maintenance-free batteries with precise voltage control

Deep Cycle

Extended charging profile for marine, RV, and golf cart batteries

2-Amp Maintain

Low amp trickle charge for battery maintenance during storage

55-Amp Fast Charge

Rapid charging for heavily discharged batteries with thermal protection

Recondition Mode

Desulfation mode to recover old or sulfated batteries

Troubleshooting

Problem Possible Cause Solution
Charger won't turn on Power issue, blown fuse, thermal shutdown Check power supply, replace fuse, allow unit to cool
Not charging battery Poor connections, dead battery, wrong mode Check clamps and connections, test battery, select correct mode
Overheating High ambient temperature, blocked vents, overload Move to cooler area, ensure ventilation, reduce charge rate
Error codes displayed Reverse polarity, bad battery, internal fault Check connections, test battery, consult manual
Engine start not working Weak battery, poor connections, safety timeout Ensure battery has some charge, clean terminals, wait 3 minutes
Display flashing Low voltage, bad connection, fault condition Check battery voltage, ensure good contact, reset charger

Error Codes

  • E1: Reverse polarity - Check and correct battery connections
  • E2: Battery voltage too low - Battery may be dead or damaged
  • E3: Battery voltage too high - Disconnect and check battery
  • E4: Charger overheating - Allow to cool, ensure ventilation
  • E5: Output shorted - Check for short circuits in cables
  • E6: Internal fault - Contact service center

Manual Downloads

Current Model Manuals

SC1355

Wheeled Battery Charger 55/10/2/200A

SC1353

Wheeled Battery Charger 50/10/2/200A

SC1352

Wheeled Battery Charger 30/10/2/200A

SC1351

Wheeled Battery Charger 15/10/2/100A

Popular Previous Models

SC1200A

Wheeled Charger 100/30/10/2A

SC1000A

Wheeled Charger 50/25/10/2A

SE-1250A

Wheeled Charger 125/30/10/2A

SE-1050A

Wheeled Charger 50/15/10/2A

Note: For models not listed here, please visit the Schumacher Support Website for complete documentation.