Schumacher Speed Charge

User Manual & Installation Guide

Battery Charger & Maintainer

Installation Guide

Tools Needed:

  • Safety glasses
  • Adjustable wrench
  • Wire cutters/strippers
  • Screwdrivers (flat and Phillips)
  • Multimeter

Step-by-Step Installation

  1. Safety First: Wear safety glasses and gloves. Work in a well-ventilated area away from sparks or flames.
  2. Battery Preparation: Ensure battery is in a stable, level position. Clean battery terminals if corroded.
  3. Power Connection: Connect charger to a properly grounded 120V, 60Hz, AC outlet. Do not use an extension cord.
  4. Battery Connection: Connect RED clamp to POSITIVE (+) battery terminal. Connect BLACK clamp to NEGATIVE (-) battery terminal or vehicle chassis ground.
  5. Charger Settings: Select appropriate charge mode based on battery type (Standard, AGM, Gel, or Lithium).
  6. Initialization: The charger will perform an automatic battery test before beginning the charging process.
  7. Monitoring: Monitor initial charging process for proper operation. LED indicators will show charging status.
Warning: Always connect charger to battery before plugging into power outlet. Disconnect from power before removing clamps.

Specifications

Model Series SC1500 / SC2000
Type Fully Automatic Battery Charger
Color Black with Yellow Accents
Charge Rate 15A / 20A (Selectable)
Battery Compatibility 6V / 12V Standard, AGM, Gel, Lithium
Control Type Microprocessor Controlled with LED Display
Input Voltage 120V AC, 60Hz
Output Voltage 6V / 12V DC
Power Requirements 120V, 60Hz, 10A
Dimensions (HxWxD) 12 x 8 x 6 inches
Weight 8.5 lbs
Charge Modes Standard, AGM, Gel, Lithium, Maintain

Warranty Information

  • Full Warranty: 3 years parts and labor
  • Transformer Warranty: 5 years on heavy-duty transformer
  • Additional Coverage: Optional extended warranty available

For warranty service, contact Schumacher Customer Service at 1-800-621-5485 or visit SchumacherElectric.com

Key Features

Microprocessor Controlled

Advanced microprocessor automatically adjusts charge rate based on battery condition, preventing overcharging and undercharging.

Multi-Stage Charging

Four-stage charging process (Bulk, Absorption, Float, Maintenance) ensures optimal battery health and maximum battery life.

Reverse Polarity Protection

Built-in safety feature prevents damage if clamps are accidentally connected to wrong battery terminals.

Battery Reconditioning

Special mode helps recover lightly sulfated batteries, potentially restoring lost capacity and extending battery life.

LED Status Indicators

Clear visual indicators show charging status, battery condition, and any error conditions at a glance.

Spark-Free Technology

Special circuitry prevents sparks when connecting clamps, reducing risk of battery explosion in flammable environments.

Charging Modes Explained

Standard Mode

For conventional flooded lead-acid batteries, provides optimal charging for automotive applications

AGM Mode

Specifically designed for Absorbent Glass Mat batteries with precise voltage control

Gel Mode

Lower voltage setting for gel cell batteries to prevent overcharging and damage

Lithium Mode

Special algorithm for lithium-ion batteries with different charge characteristics

Maintain Mode

Float charging for long-term battery maintenance without overcharging

Recondition Mode

Desulfation mode for recovering sulfated batteries with controlled pulses

Troubleshooting

Problem Possible Cause Solution
Charger won't turn on Power issue, blown fuse, faulty outlet Check power supply, replace fuse if needed, try different outlet
No charge output Bad connections, dead battery, wrong mode Check clamp connections, test battery voltage, select correct mode
Charger shuts off early Overheating, battery defect, high resistance Allow to cool, check battery condition, clean terminals
Error light flashing Reverse polarity, bad battery, connection issue Check connection polarity, test battery, ensure good contact
Slow charging Low input voltage, long cables, battery size Check outlet voltage, use shorter cables, select higher amp setting
Overheating Ventilation blocked, high ambient temperature Ensure proper ventilation, move to cooler location

Error Codes & LED Indicators

  • Solid Green: Charging normally - No action needed
  • Flashing Green: Maintenance charging - Battery fully charged
  • Solid Red: Error condition - Check connections and battery
  • Flashing Red: Reverse polarity - Disconnect and check connections
  • Red/Green Alternating: Battery defect - Test battery condition
  • All LEDs Off: No power - Check power source and fuse

Manual Downloads

Current Model Manuals

SC1500

15A Speed Charge Pro

SC2000

20A Speed Charge Pro

SC1200

12A Speed Charge

SC1000

10A Speed Charge Lite

Popular Previous Models

SC800

8A Automatic Charger

SC600

6A Battery Maintainer

SC3000

30A Industrial Charger

SC2500

25A Heavy Duty Charger

Note: For models not listed here, please visit the Schumacher Support Website for complete documentation.