Schumacher Electric Battery Charger

User Manual & Installation Guide

Multi-Model Series

Installation Guide

Tools Needed:

  • Adjustable wrench
  • Wire strippers
  • Screwdrivers (flat and Phillips)
  • Multimeter
  • Safety gloves and goggles

Step-by-Step Installation

  1. Choose Installation Location: Select a dry, well-ventilated area away from flammable materials and moisture.
  2. Inspect Battery: Check battery for cracks, leaks, or damage before connecting charger.
  3. Connect Battery Cables: Connect RED clamp to POSITIVE (+) terminal, BLACK clamp to NEGATIVE (-) terminal.
  4. Power Connection: Plug charger into a properly grounded 120V, 60Hz outlet. Ensure outlet is GFCI protected.
  5. Select Charge Mode: Choose appropriate charging mode based on battery type (Standard, AGM, Gel, Deep Cycle).
  6. Set Charge Rate: Select appropriate amperage setting based on battery size and condition.
  7. Initial Test: Monitor charger for first 15 minutes to ensure proper operation and no overheating.
Warning: Always wear protective equipment when handling batteries. Ensure proper ventilation to prevent hydrogen gas accumulation.

Specifications

Model Series SC1500 / SC1325 / SC1200
Type Automatic Battery Charger/Maintainer
Color Black / Yellow
Input Voltage 120V AC, 60Hz
Output Voltage 6V / 12V Selectable
Charge Rate 2A / 10A / 50A (Model Dependent)
Battery Compatibility Standard, AGM, Gel, Deep Cycle
Display Type LED Indicators / Digital Display
Safety Features Reverse Polarity, Overheat, Short Circuit Protection
Dimensions (HxWxD) 25 x 18 x 12 cm
Weight 3.2 kg
Cable Length 1.5 meters

Warranty Information

  • Full Warranty: 3 years parts and labor
  • Microprocessor Warranty: 5 years on control board
  • Additional Coverage: Optional extended warranty available

For warranty service, contact Schumacher Customer Service at 1-800-621-5485 or visit SchumacherElectric.com

Key Features

Microprocessor Controlled

Advanced microprocessor automatically adjusts charge rate based on battery condition, preventing overcharging and undercharging.

Multi-Stage Charging

Automatic multi-stage charging (Bulk, Absorption, Float) ensures optimal battery health and maximum battery life.

Battery Recondition Mode

Special recondition mode helps recover deeply discharged batteries and prevent sulfation buildup.

AGM/Gel Compatible

Specifically designed to safely charge AGM (Absorbent Glass Mat) and Gel cell batteries without damage.

Engine Start Assist

High-amperage models include engine start function to help start vehicles with weak batteries.

Float Mode Monitoring

Automatically switches to float mode once battery is fully charged, maintaining optimal charge without overcharging.

Charging Modes Explained

Standard Charge

For regular lead-acid batteries, provides optimal charging for automotive applications

AGM Mode

Special algorithm for AGM batteries, prevents overcharging and gas generation

Deep Cycle

Extended absorption time for deep cycle batteries used in marine/RV applications

Recondition

Desulfation mode to recover old or sulfated batteries

Maintenance

Float charge mode for long-term battery maintenance during storage

Engine Start

High current mode to assist starting vehicles with weak batteries

Troubleshooting

Problem Possible Cause Solution
Charger won't turn on Power issue, blown fuse, faulty outlet Check power supply, replace fuse, test outlet with another device
Not charging battery Reverse polarity, bad connections, dead battery Check connections, ensure proper polarity, test battery voltage
Overheating Poor ventilation, high ambient temperature, overload Move to cooler area, ensure ventilation, reduce charge rate
Error lights flashing Faulty battery, reverse polarity, short circuit Disconnect and reconnect, check battery condition, inspect cables
Slow charging Low input voltage, long cables, battery sulfation Check outlet voltage, use shorter cables, try recondition mode
Spark when connecting Charger turned on, battery load present Always connect cables with charger off, connect negative last

Error Codes & Indicators

  • Red Flashing: Reverse polarity - Disconnect and correct connections
  • Green/Red Alternating: Battery voltage too low - Use manual mode or replace battery
  • Solid Red: Charging in progress - Normal operation
  • Solid Green: Charge complete / Maintenance mode - Normal operation
  • All Lights Flashing: Overheat condition - Allow to cool, improve ventilation
  • No Lights: No power / Internal fault - Check power supply, contact service

Manual Downloads

Current Model Manuals

SC1500

15A Automatic Charger/Maintainer

SC1325

25A Engine Starter/Charger

SC1200

10A Fully Automatic Charger

SC1353

35A Fast Charger/Engine Starter

Popular Previous Models

SC1001A

10A Manual Charger

SC6005

6A Automatic Charger

SC2000

20A Charger/Maintainer

SC800

8A Automatic Charger

Note: For models not listed here, please visit the Schumacher Support Website for complete documentation.