The Schumacher SE 82-6 is a fully automatic battery charger and maintainer designed for 6V and 12V lead-acid batteries, including standard, AGM, and gel cell types. It features microprocessor-controlled charging, a digital display, automatic voltage detection, multi-stage charging (bulk, absorption, float), reverse hook-up protection, and a battery reconditioning mode. Below are key sections for safety, features, operation, specifications, and troubleshooting.
Key components: Microprocessor control unit, Digital LED display, Charging clamps (red/black), AC power cord, Mode selection buttons.
| Feature | Description |
|---|---|
| Automatic Voltage Detection | Detects 6V or 12V battery automatically |
| Digital Display | Shows battery voltage, charge status, and error codes |
| Multi-Stage Charging | Bulk, Absorption, and Float modes for optimal charging |
| Battery Reconditioning Mode | Helps recover deeply discharged batteries |
| Reverse Polarity Protection | Prevents damage if clamps are connected incorrectly |
| Spark-Proof Technology | Safe connection to battery terminals |
| Fully Automatic Operation | Charges and maintains without manual intervention |
| Compact Design | Portable for garage, workshop, or storage |
| Compatible Battery Types | Standard, AGM, Gel Cell (flooded and sealed) |
| AC Input | 120V AC, 60Hz standard household outlet |
Read all instructions before use. Use in well-ventilated area.
WARNING! Risk of explosion or acid burn. Follow instructions precisely. Do not disassemble charger.
Unpack charger and inspect for damage. Ensure battery is in safe, stable location.
CAUTION! Ensure proper ventilation. Do not place charger directly above battery.
Front Panel: POWER button, MODE button, Digital Display, Status LEDs.
Display Indicators: Battery Voltage (e.g., 12.6V), Charging Status (e.g., CHARGING, FULL), Error Codes (e.g., E1, E2).
Mode Button: Cycles through charging options: STANDARD (default), AGM/GEL, RECONDITION. Press and hold for 3 seconds to select.
Status LEDs: POWER (green), CHARGING (flashing yellow), FULL (solid green), FAULT (red).
For 6V or 12V lead-acid batteries.
Tip: For maintenance charging, leave connected; charger switches to float mode automatically.
Use for deeply discharged or sulfated batteries.
WARNING! Reconditioning may not revive all batteries. Do not use on damaged or leaking batteries.
Unplug and clean after each use. Store in dry, cool place.
Cleaning: Wipe with dry cloth. Do not use liquids or solvents.
Storage: Coil cords neatly. Keep away from children and moisture.
CAUTION! Inspect clamps and cords regularly for damage. Do not use if damaged.
FCC Part 15: Class B digital device; complies with interference limits. UL Listed. Copyright © Schumacher Electric Corporation. For support, visit www.schumacherelectric.com or contact 1-800-621-5485.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Display blank | No AC power | Check outlet; ensure charger is plugged in securely. |
| "E1" error code | Reverse polarity | Disconnect and reconnect clamps correctly (RED to +, BLACK to -). |
| "E2" error code | Battery voltage too low or high | Check battery voltage manually; replace if below 3V or above 18V. |
| Not charging | Poor connection | Clean battery terminals; ensure clamps have solid contact. |
| Charger overheats | Ventilation blocked | Move to cooler area; ensure vents are clear. |
| Battery not holding charge | Battery defective | Test battery with load tester; replace if necessary. |
Reset: Unplug charger for 2 minutes to reset microprocessor.
Service: 1-800-621-5485; www.schumacherelectric.com