The Schumacher SC1307 is a fully automatic 15 Amp 6/12 Volt battery charger and maintainer with microprocessor-controlled charging, multi-stage charging (bulk, absorption, float), battery reconditioning mode, reverse hook-up protection, and a digital display showing voltage, amperage, and charge status. It is designed for charging and maintaining standard, AGM, gel, and deep-cycle batteries. Below are key sections for safety, features, installation, operation, and troubleshooting.
Key components: Digital Display, Control Buttons, Charging Clamps (red/black), AC Power Cord, Battery Type Selector.
| Feature | Description |
|---|---|
| Digital Display | Shows battery voltage, charging amps, and status codes |
| Fully Automatic Operation | Microprocessor controls charging stages automatically |
| Multi-Stage Charging | Bulk, Absorption, Float modes for optimal battery health |
| Battery Reconditioning | Desulfation mode to recover weakened batteries |
| Battery Type Selection | Settings for Standard, AGM, Gel, and Deep-Cycle batteries |
| Reverse Polarity Protection | Prevents damage if clamps are connected incorrectly |
| Spark-Proof Technology | Safe connection after clamps are attached to battery |
| Maintainer Function | Float mode maintains battery at full charge indefinitely |
| 15 Amp Output | Fast charging for automotive and marine batteries |
| 6V/12V Selection | Switch between 6-volt and 12-volt battery systems |
Read all instructions before use. Use in well-ventilated area.
WARNING! Battery gases can explode. Do not use near flammable materials. Use only as directed.
Unpack charger and inspect for damage. Place on stable, dry surface.
CAUTION! Ensure clamps do not touch each other or any metal surface after connection to battery.
Front Panel: Digital Display, BATTERY TYPE Button, MODE Button, 6V/12V Switch.
Display Indicators: Battery Voltage (e.g., 12.6V), Charging Amps (e.g., 8.5A), Status Codes (CHG=Charging, FUL=Full, ERR=Error).
Controls: BATTERY TYPE - Selects battery chemistry. MODE - Toggles between Charge, Maintain, and Recondition modes. 6V/12V Switch - Sets output voltage. Automatic operation begins once AC power is connected and clamps are properly attached.
For 12V Automotive Battery (Standard Type):
Tip: For deeply discharged batteries (<10V), charger may enter recovery mode automatically.
Float maintenance keeps battery at optimal charge for storage.
Note: Maintenance mode is safe for AGM and Gel batteries, preventing overcharging.
Reconditioning (Desulfation) mode attempts to recover sulfated batteries.
WARNING! Not all batteries can be recovered. Do not use on new or healthy batteries unnecessarily.
Unplug and disconnect clamps before cleaning. Wipe with dry cloth. Store in cool, dry place.
CAUTION! Do not expose to rain or moisture. Keep clamps clean and free of corrosion.
FCC Part 15: Class B digital device; complies with limits for residential use. Copyright © Schumacher Electric Corporation. For support, visit www.schumacherelectric.com or contact 1-800-621-5485.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Display blank/no power | AC power not connected | Check outlet; ensure power cord is fully plugged in. |
| "ERR" on display | Reverse polarity or bad connection | Disconnect and reconnect clamps correctly (red to +, black to -). |
| Not charging (0.0A) | Battery fully charged or deeply discharged | If battery voltage <10V, wait for recovery mode. If "FUL" shows, battery is full. |
| Charger gets hot | Normal during high-rate charging | Ensure ventilation; reduce charge rate if possible. If excessively hot, unplug. |
| Clamps sparking | Connected while plugged in | ALWAYS unplug AC power before connecting/disconnecting clamps. |
Reset: Unplug charger, disconnect clamps, wait 2 minutes, then reconnect.
Service: 1-800-621-5485; www.schumacherelectric.com