The Schumacher SE-82-6 is a fully automatic microprocessor-controlled battery charger and maintainer designed for 6V and 12V lead-acid batteries, including standard, AGM, gel cell, and deep-cycle types. It features automatic voltage detection, multi-stage charging (bulk, absorption, float), reverse hook-up protection, and a digital display showing battery status, voltage, and charge progress. Below are key sections for safety, features, installation, operation, and troubleshooting.
Key components: Microprocessor control unit, Digital LCD display, Charging clamps (red/black), AC power cord, Mode selection buttons.
| Feature | Description |
|---|---|
| Automatic Voltage Detection | Detects 6V or 12V battery automatically |
| Multi-Stage Charging | Bulk, Absorption, Float modes for optimal charging |
| Battery Type Support | Standard, AGM, Gel Cell, Deep-Cycle |
| Digital Display | Shows voltage, charge status, error codes |
| Reverse Polarity Protection | Prevents damage from incorrect clamp connection |
| Spark-Proof Technology | Safe connection after clamps are attached |
| Maintainer Mode | Float mode maintains battery at full charge |
| Compact Design | Lightweight with integrated cable storage |
| AC Input | 120V, 60Hz standard household outlet |
| Charge Rate | 2A, 6A, and 10A selectable modes |
Read all instructions before use. Use in well-ventilated area.
WARNING! Risk of explosion or acid burn. Follow instructions precisely. Do not disassemble charger.
Unpack and inspect contents. Place charger on stable, dry surface.
CAUTION! Connect clamps to battery before plugging into AC outlet. Disconnect in reverse order.
Front Panel: POWER button, MODE selector (2A/6A/10A), ENTER button.
Display Indicators: Battery icon (charging/maintaining), Voltage readout, Error codes, Charge progress bar.
Charging Stages: BULK (constant current), ABSORPTION (constant voltage), FLOAT (maintenance voltage). Status Lights: RED (charging), YELLOW (absorption), GREEN (float/maintain).
Automatic charging for 6V/12V batteries.
Tip: For deeply discharged batteries, charger may take several minutes to recognize battery before beginning charge cycle.
Float/maintain mode keeps battery at optimal charge during storage.
Note: Ideal for seasonal vehicles, boats, and equipment in storage.
Display shows error codes for troubleshooting:
| Code | Meaning | Action |
|---|---|---|
| E1 | Reverse polarity detected | Check clamp connections |
| E2 | Battery voltage too low/high | Check battery condition |
| E3 | Overheating | Allow charger to cool |
| E4 | Bad battery connection | Clean terminals, secure clamps |
| E5 | Charger malfunction | Contact service center |
Unplug and clean with dry cloth after use. Store in cool, dry place.
CAUTION! Do not expose to rain or moisture. Keep clamps clean and free of corrosion.
FCC Part 15: Class B digital device; complies with interference limits. UL Listed. Copyright © Schumacher Electric Corporation. For support, visit www.schumacherelectric.com or contact 1-800-621-5485.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display/power | AC outlet dead/not plugged in | Check outlet; ensure plug is fully inserted |
| Charger not starting | Battery voltage too low | Try manual override mode; check battery |
| Error code displayed | See error code table | Refer to Error Codes section |
| Slow charging | Large battery/small charge rate | Select higher amp setting (6A or 10A) |
| Clamps heating | Poor connection | Clean battery terminals; ensure solid contact |
| Charger stops early | Battery defective/overheating | Test battery; allow to cool if hot |
Reset: Unplug from AC and battery for 2 minutes to reset microprocessor.
Service: 1-800-621-5485; www.schumacherelectric.com