The Schumacher SC1309 is a fully automatic battery charger and maintainer designed for 6V and 12V lead-acid batteries, including standard, AGM, gel-cell, and deep-cycle batteries. It features microprocessor-controlled charging, automatic voltage detection, float-mode monitoring, and reverse hook-up protection. Below are key sections for safety, features, operation, maintenance, and troubleshooting.
Key components: Microprocessor control unit, Charging clamps (red/black), AC power cord, LED status indicators, Battery type selector.
| Feature | Description |
|---|---|
| Microprocessor Control | Automatically adjusts charge rate and maintains battery |
| Automatic Voltage Detection | Detects 6V or 12V battery automatically |
| Float-Mode Monitoring | Maintains optimal charge without overcharging |
| Reverse Polarity Protection | Alerts if clamps are connected incorrectly |
| Multi-Battery Support | Charges standard, AGM, gel-cell, and deep-cycle |
| LED Status Indicators | Shows charging, maintenance, and fault conditions |
| Fully Automatic Operation | No manual adjustment needed after connection |
| Compact Design | Lightweight and portable for easy storage |
Read all instructions before use to prevent injury or damage.
WARNING! Risk of explosive gases. Keep charger away from battery during charging. Do not smoke or use open flame near battery.
Unpack and inspect contents. Ensure charger is on stable, dry surface.
CAUTION! Do not connect to AC power before attaching to battery. Ensure clamps do not touch each other or metal surfaces.
Front Panel: POWER LED (green), CHARGING LED (red), MAINTENANCE LED (green), FAULT LED (red).
LED Status Guide:
Operation: Fully automatic - no user controls beyond connection.
Follow these steps for safe and effective charging.
Tip: For deeply discharged batteries, charger may take several hours to reach full charge. If FAULT LED lights, check connections and battery condition.
After full charge, charger enters float maintenance mode to prevent overcharging.
Note: For long-term storage, check battery and charger monthly for proper operation.
Unplug and disconnect from battery before cleaning. Wipe with dry cloth only; do not use liquids or solvents.
Store in cool, dry place. Keep clamps clean and free of corrosion. Coil cord neatly to prevent damage.
CAUTION! Do not expose to rain or moisture. Do not store near heat sources or flammable materials.
FCC Part 15: Class B digital device; complies with interference limits for residential use. UL Listed. Copyright © Schumacher Electric Corporation. All trademarks are property of their respective owners. For support, visit www.schumacherelectric.com or contact 1-800-621-5485.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No LED indicators | No AC power | Check outlet; ensure cord is fully plugged in. |
| FAULT LED illuminated | Reverse connection or bad battery | Disconnect and reconnect clamps correctly. Test battery voltage. |
| CHARGING LED not on | Battery already charged or defective | Check battery voltage. If above 12.6V, battery may be charged. |
| Charger gets warm | Normal operation | Some warmth is normal during charging cycle. |
| Battery not holding charge | Old or defective battery | Test battery; may need replacement. |
| Clamps spark when connecting | Accessories on or poor connection | Ensure all vehicle accessories are off. Connect to clean terminals. |
Reset: Unplug charger, disconnect clamps, wait 30 seconds, then reconnect following proper procedure.
Service: 1-800-621-5485; www.schumacherelectric.com