Manual for Schumacher Battery Charger

User Manual & Installation Guide

Professional Series

Installation Guide

Tools Needed:

  • Safety glasses
  • Adjustable wrench
  • Wire cutters/strippers
  • Voltmeter
  • Screwdrivers (flat and Phillips)

Step-by-Step Installation

  1. Safety First: Put on safety glasses and remove all jewelry. Work in a well-ventilated area away from sparks or flames.
  2. Battery Preparation: Clean battery terminals and ensure battery is in a stable, level position.
  3. Connection Sequence: Connect RED clamp to POSITIVE (+) battery terminal first. Then connect BLACK clamp to NEGATIVE (-) terminal or vehicle chassis ground.
  4. Power Connection: Plug charger into a properly grounded 120V AC outlet. Do not use extension cords.
  5. Charger Settings: Select appropriate charge rate based on battery type and capacity. Refer to battery manufacturer specifications.
  6. Initial Test: Verify proper connection by checking charger display/indicators. Ensure no sparking occurs during connection.
  7. Monitoring: Monitor charging process periodically. Do not leave unattended for extended periods during initial charge.
Warning: Always follow proper safety procedures when working with batteries. Explosive gases can be present. Keep sparks and flames away from battery area.

Specifications

Model Series SC1355 / SC1353
Type Fully Automatic Battery Charger
Color Black / Yellow
Input Voltage 120V AC, 60Hz
Output Voltage 6V / 12V DC
Charge Rate 2A / 10A / 50A
Battery Types Standard, AGM, Gel, Deep Cycle
Display Type LED Indicators with Digital Display
Engine Start 50A Engine Start Function
Dimensions (HxWxD) 12.5 x 9.5 x 6.5 inches
Weight 8.5 lbs
Safety Features Reverse Polarity Protection, Overheat Protection

Warranty Information

  • Full Warranty: 1 year parts and labor
  • Extended Coverage: 3 years on microprocessor
  • Additional Coverage: Optional 2-year extended warranty available

For warranty service, contact Schumacher Customer Service at 1-800-621-5485 or visit SchumacherElectric.com

Key Features

Microprocessor Controlled

Advanced microprocessor automatically adjusts charge rate based on battery condition, preventing overcharging and undercharging for optimal battery health.

Multi-Stage Charging

Three-stage charging process (bulk, absorption, float) ensures complete charging while maintaining battery longevity and performance.

Battery Recondition Mode

Special mode helps recover deeply discharged batteries by applying controlled desulfation pulses to break down sulfate crystals.

50A Engine Start

Powerful engine start function provides 50 amps of starting power to help start vehicles with weak or discharged batteries.

Battery Type Selection

Multiple settings for different battery types including standard, AGM, gel cell, and deep cycle batteries for optimal charging performance.

Safety Protection

Built-in protection against reverse polarity, short circuits, overcharging, and overheating for safe operation.

Charging Modes Explained

Standard Charge

10A charge rate for most automotive batteries, complete charging in 4-11 hours

Maintenance Charge

2A trickle charge for battery maintenance and small batteries like motorcycles

Engine Start

50A boost mode for starting vehicles with discharged batteries

AGM/Gel Mode

Special algorithm for sealed batteries requiring precise voltage control

Deep Cycle Mode

Extended absorption phase for marine and RV deep cycle batteries

Recondition Mode

Desulfation mode to recover old or sulfated batteries

Troubleshooting

Problem Possible Cause Solution
Charger won't turn on No power, blown fuse, faulty outlet Check power supply, replace fuse if needed, try different outlet
Not charging Bad connections, dead battery, wrong settings Clean connections, verify battery condition, check settings
Charger shuts off early Overheating, battery defect, charger fault Allow to cool, check battery, contact service
Error lights flashing Reverse polarity, bad battery, internal fault Check connections, test battery, consult manual
Battery gets hot Overcharging, wrong settings, battery defect Disconnect immediately, verify settings, check battery
Poor charging performance Weak battery, corroded terminals, insufficient time Clean terminals, allow adequate charging time, test battery

Error Codes & Indicators

  • Red Light Flashing: Reverse polarity detected - Check connections
  • Yellow Light Steady: Charging in progress - Normal operation
  • Green Light Flashing: Maintenance charging - Battery fully charged
  • Red/Yellow Alternating: Battery fault - Check battery condition
  • All Lights Flashing: Internal fault - Contact service center
  • No Lights: No power - Check power supply and connections

Manual Downloads

Current Model Manuals

SC1355

15/2/50A Fully Automatic Charger

SC1353

10/2A Automatic Charger

SC1325

25A Automatic Charger

SC1307

7A Automatic Charger

Popular Previous Models

SC1200A

12/2A Automatic Charger

SC1000A

10A Automatic Charger

SE1052

10/2/50A Charger/Starter

SC800A

8A Automatic Charger

Note: For models not listed here, please visit the Schumacher Support Website for complete documentation.